The e-MovAir is the best solution for challenging spaces to maintain temperature and humidity such as cultural and sports centers. It will provide beyond expected energy efficiency performance and ensure maximum hygiene in ventilation systems.

R410A
Capacidad frigorífica

20 - 140 kW

Capacidad calorífica

17 - 146 kW

Caudal de aire

3500 - 30000 m3/h

Nomenclatura del modelo

eM A 24 B A C H D 140 E

A eM = e-MovAir

B Caudal de aire (xx000)

C Rango de capacidad

D H = Bomba de calor

E A = Condensada por aire

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Eer Net
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  •  
  • eM03AH025
  • 4
  • 156
  • -
  •  
  • 22.6
  • 4.9
  • 4.61
  •  
  • 3500
  • 3500
  • 4500
  •  
  • -
  • 9 / 18
  • 9 / 18
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 11
  •  
  • 4
  •  
  • 18.1
  • 3.2
  •  
  • 48
  • 76
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM04AH028
  • 3.9
  • 155
  • -
  •  
  • 25.7
  • 6.4
  • 4
  •  
  • 3500
  • 4500
  • 5000
  •  
  • -
  • 12 / 24
  • 12 / 24
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 12
  •  
  • 4.2
  •  
  • 24.6
  • 3.24
  •  
  • 53
  • 82
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM05AH030
  • 4
  • 156
  • -
  •  
  • 37.4
  • 9.6
  • 3.91
  •  
  • 4000
  • 5500
  • 5500
  •  
  • -
  • 12 / 24
  • 12 / 24
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 12
  •  
  • 3.7
  •  
  • 29.8
  • 3.16
  •  
  • 58
  • 87
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM06AH035
  • 4.3
  • 169
  • -
  •  
  • 34.2
  • 6.6
  • 5.22
  •  
  • 5500
  • 5500
  • 6350
  •  
  • -
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 18
  •  
  • 3.9
  •  
  • 23.2
  • 4.47
  •  
  • 53
  • 79
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM07AH040
  • 4.4
  • 174
  • -
  •  
  • 36.1
  • 8.2
  • 4.41
  •  
  • 6300
  • 7200
  • 8280
  •  
  • -
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 24
  •  
  • 4.2
  •  
  • 40
  • 5.22
  •  
  • 58
  • 85
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM09AH055
  • 4.4
  • 171
  • -
  •  
  • 60.5
  • 15
  • 4.02
  •  
  • 8300
  • 9900
  • 9900
  •  
  • -
  • 24 / 48
  • 24 / 48
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 24
  •  
  • 4
  •  
  • 49.9
  • 2.96
  •  
  • 65
  • 93
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM10AH070
  • 4.1
  • 160
  • -
  •  
  • 55.7
  • 11.9
  • 4.7
  •  
  • 8600
  • 8600
  • 10000
  •  
  • -
  • 24 / 48
  • 24 / 48
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 2
  • 30
  •  
  • 3.9
  •  
  • 45.8
  • 4.58
  •  
  • 62
  • 90
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM13AH085
  • 4.6
  • 180
  • -
  •  
  • 84.4
  • 18.1
  • 4.67
  •  
  • 10000
  • 13500
  • 15600
  •  
  • -
  • 36 / 72
  • 36 / 72
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 20+20
  •  
  • 4
  •  
  • 70
  • 3.79
  •  
  • 66
  • 87
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM17AH100
  • 4.3
  • 170
  • -
  •  
  • 107.2
  • 29.1
  • 3.68
  •  
  • 15600
  • 18500
  • 18500
  •  
  • -
  • 36 / 72
  • 36 / 72
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 20+20
  •  
  • 4.1
  •  
  • 102.3
  • 2.96
  •  
  • 72
  • 95
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM18AH110
  • 4.4
  • 171
  • -
  •  
  • 106.1
  • 23.8
  • 4.47
  •  
  • 17500
  • 17500
  • 20300
  •  
  • -
  • 48 / 96
  • 48 / 96
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 21+21
  •  
  • 4
  •  
  • 99.2
  • 3.19
  •  
  • 71
  • 93
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM24AH140
  • 4.8
  • 187
  • -
  •  
  • 140.8
  • 31.7
  • 4.45
  •  
  • 20000
  • 24000
  • 27600
  •  
  • -
  • 48 / 96
  • 48 / 96
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 3
  • 18+27
  •  
  • 4.1
  •  
  • 118.6
  • 3.14
  •  
  • 74
  • 91
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM30AH170
  • 4.2
  • 166
  • -
  •  
  • 166.3
  • 45.5
  • 3.7
  •  
  • 26000
  • 30000
  • 30000
  •  
  • -
  • 66 / 126
  • 66 / 126
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 3
  • 18+27
  •  
  • 3.7
  •  
  • 147
  • 2.7
  •  
  • 79
  • 97
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.

  1. Cooling mode : According to EN14511 nominal conditions
    • Outdoor temperature 35°C DB
    • Indoor temperature 27°C DB / 19°C WB
  2. Heating mode : According to EN14511 nominal conditions
    • Outdoor temperature 7°C DB / 6°C WB
    • Indoor temperature 20°C DB
  3. SEER in accordance with standard EN14825.
  4. Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Space heating energy efficiency following Ecodesign regulation EU 2016/2281.
  7. Ventilation data - Supply fan ESP: 250 Pa / Exhaust fan ESP: 150Pa / Fresh air percentage: 80%

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Eer Net
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  •  
  • eM03AH025
  • 4
  • 156
  • -
  •  
  • 22.6
  • 4.9
  • 4.61
  •  
  • 3500
  • 3500
  • 4500
  •  
  • -
  • 9 / 18
  • 9 / 18
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 11
  •  
  • 4
  •  
  • 18.1
  • 3.2
  •  
  • 48
  • 76
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM04AH028
  • 3.9
  • 155
  • -
  •  
  • 25.7
  • 6.4
  • 4
  •  
  • 3500
  • 4500
  • 5000
  •  
  • -
  • 12 / 24
  • 12 / 24
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 12
  •  
  • 4.2
  •  
  • 24.6
  • 3.24
  •  
  • 53
  • 82
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM05AH030
  • 4
  • 156
  • -
  •  
  • 37.4
  • 9.6
  • 3.91
  •  
  • 4000
  • 5500
  • 5500
  •  
  • -
  • 12 / 24
  • 12 / 24
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 12
  •  
  • 3.7
  •  
  • 29.8
  • 3.16
  •  
  • 58
  • 87
  •  
  • 12.2
  • 19.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM06AH035
  • 4.3
  • 169
  • -
  •  
  • 34.2
  • 6.6
  • 5.22
  •  
  • 5500
  • 5500
  • 6350
  •  
  • -
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 18
  •  
  • 3.9
  •  
  • 23.2
  • 4.47
  •  
  • 53
  • 79
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM07AH040
  • 4.4
  • 174
  • -
  •  
  • 36.1
  • 8.2
  • 4.41
  •  
  • 6300
  • 7200
  • 8280
  •  
  • -
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 24
  •  
  • 4.2
  •  
  • 40
  • 5.22
  •  
  • 58
  • 85
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM09AH055
  • 4.4
  • 171
  • -
  •  
  • 60.5
  • 15
  • 4.02
  •  
  • 8300
  • 9900
  • 9900
  •  
  • -
  • 24 / 48
  • 24 / 48
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 1
  • 24
  •  
  • 4
  •  
  • 49.9
  • 2.96
  •  
  • 65
  • 93
  •  
  • 22.8
  • 36.5
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM10AH070
  • 4.1
  • 160
  • -
  •  
  • 55.7
  • 11.9
  • 4.7
  •  
  • 8600
  • 8600
  • 10000
  •  
  • -
  • 24 / 48
  • 24 / 48
  • Capacity depends on air and water temperatures.
  •  
  • 1
  • 2
  • 30
  •  
  • 3.9
  •  
  • 45.8
  • 4.58
  •  
  • 62
  • 90
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM13AH085
  • 4.6
  • 180
  • -
  •  
  • 84.4
  • 18.1
  • 4.67
  •  
  • 10000
  • 13500
  • 15600
  •  
  • -
  • 36 / 72
  • 36 / 72
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 20+20
  •  
  • 4
  •  
  • 70
  • 3.79
  •  
  • 66
  • 87
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM17AH100
  • 4.3
  • 170
  • -
  •  
  • 107.2
  • 29.1
  • 3.68
  •  
  • 15600
  • 18500
  • 18500
  •  
  • -
  • 36 / 72
  • 36 / 72
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 20+20
  •  
  • 4.1
  •  
  • 102.3
  • 2.96
  •  
  • 72
  • 95
  •  
  • 43.5
  • 69.8
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM18AH110
  • 4.4
  • 171
  • -
  •  
  • 106.1
  • 23.8
  • 4.47
  •  
  • 17500
  • 17500
  • 20300
  •  
  • -
  • 48 / 96
  • 48 / 96
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 2
  • 21+21
  •  
  • 4
  •  
  • 99.2
  • 3.19
  •  
  • 71
  • 93
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM24AH140
  • 4.8
  • 187
  • -
  •  
  • 140.8
  • 31.7
  • 4.45
  •  
  • 20000
  • 24000
  • 27600
  •  
  • -
  • 48 / 96
  • 48 / 96
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 3
  • 18+27
  •  
  • 4.1
  •  
  • 118.6
  • 3.14
  •  
  • 74
  • 91
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.
  •  
  • eM30AH170
  • 4.2
  • 166
  • -
  •  
  • 166.3
  • 45.5
  • 3.7
  •  
  • 26000
  • 30000
  • 30000
  •  
  • -
  • 66 / 126
  • 66 / 126
  • Capacity depends on air and water temperatures.
  •  
  • 2
  • 3
  • 18+27
  •  
  • 3.7
  •  
  • 147
  • 2.7
  •  
  • 79
  • 97
  •  
  • 72.3
  • 116
  • Depends on operating conditions.
  • Depends on operating conditions.

  1. Cooling mode : According to EN14511 nominal conditions
    • Outdoor temperature 35°C DB
    • Indoor temperature 27°C DB / 19°C WB
  2. Heating mode : According to EN14511 nominal conditions
    • Outdoor temperature 7°C DB / 6°C WB
    • Indoor temperature 20°C DB
  3. SEER in accordance with standard EN14825.
  4. Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Space heating energy efficiency following Ecodesign regulation EU 2016/2281.
  7. Ventilation data - Supply fan ESP: 250 Pa / Exhaust fan ESP: 150Pa / Fresh air percentage: 80%

FGAS compliant

FGAS compliant

EcoDesign compliant

EcoDesign compliant

Beyond expectation!

High energy efficiency

Designed with smart features and highly innovative components that provide beyond expectation energy efficiency performance.

Maximum hygiene

e-MovAir is fully compliant with the VDI 6022 certification, ensuring maximum hygiene in ventilation systems.

Extra comfort

Created to supply high fresh air rates, this solution combines comfort with superior indoor air quality.

All year-long operation

With this unit you won’t need a defrost cycle, preventing any temperature drop and providing fresh clean air 365 days per year.

Easy installation

This plug-and-play air handling unit is easy to install and does not require any additional installation operation.

Customized insulation

Two insulation options are available: thermal insulation and acoustic insulation.

Aplicaciones y Mercados

e-MovAir para su aplicación

Cultural and sport centres

Industries

¿ Alguna Pregunta?

Contactar para más información

Contactar a Lennox
¿ Alguna Dificultad?

Contacte con el servicio técnico e-MovAir

Contactar a Lennox

Recursos y archivos del producto

Lennox service catalogue

Lennox EMEA Corporate Brochure

e-Movair Manual de installación, uso y mantenimiento

Servicios HVAC

Saque el máximo partido a su equipo con la ayuda adicional que le ofrecen las personas que mejor conocen el producto

Mantenimiento

Soporte normativo

Modernización del sistema

Optimización del sistema

Reparaciones

Piezas de Repuestos

¿Necesita asistencia del equipo técnico?

Hable con nuestro equipo de servicio y obtenga toda la ayuda que necesita para solucionar problemas y realizar el mantenimiento de su equipo Lennox

Contactar a Lennox