eCOMFORT_DBOX_02_HP

Air-cooled chillers

eComfort R410a

eCOMFORT_DBOX_02_HP

The eComfort is dedicated to a variety application. Compact and discreet, it will adapt to every building’s architecture. Economic and ecologic this solution ensures excellent seasonal energy efficiencies and precise water temperature control.

Cooling capacity

20 - 180 kW

Heating capacity

20 - 190 kW

Model Nomenclature

G A A B C C 020 D S E M F 2 G M H

A G = eComfort

B A = Air cooled unit

C C = Cooling only unit - H = Heat pump unit

D 020 = Approximate power in kW

E S = Single circuit - D = Double circuit

F M = Refrigerant R410A

G 2 = Revision number

H M = 400V/3/50Hz

Model Specification

  • Hydraulic Data
  • Product Index
  • Type
  • Diameter
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Absorbed Power - kW
  • Eer
  • Eurovent Energy Class
  • Application Type
  • Fan Type
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Seasonal Energy Performance Ratio High Temp
  • Seasonal Energy Performance Ratio Med Temp
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Total Refrigirant Load R4101a
  • Evaporator Data
  • Nominal Water Flow Rate
  • Nominal pressure drop - kPa
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  •  
  • GAC020S
  • Threaded male
  • 1 1/2.
  •  
  • 20.1
  • 6
  • 3.36
  • A
  • Comfort Application
  • EC Fans
  • 194
  • 4.93
  • -
  • -
  •  
  • 1
  • 2
  • 3.3
  •  
  • 3.47
  • 17
  •  
  • 72.4
  •  
  • 9.9
  • 52.1
  • 16.6
  • 10
  •  
  • GAC025S
  • Threaded male
  • 1 1/2.
  •  
  • 20.1
  • 6
  • 3.36
  • A
  • Comfort Application
  • Standard Fans
  • 184
  • 4.67
  • -
  • -
  •  
  • 1
  • 2
  • 3.3
  •  
  • 4.24
  • 25
  •  
  • 74
  •  
  • 12.2
  • 61.7
  • 18.8
  • 10
  •  
  • GAC030S
  • Threaded male
  • 1 1/2.
  •  
  • 20.1
  • 6
  • 3.36
  • A
  • Process Application
  • Standard Fans
  • -
  • -
  • 6.64
  • 4.64
  •  
  • 1
  • 2
  • 4.4
  •  
  • 5.47
  • 27
  •  
  • 74
  •  
  • 15.3
  • 88.7
  • 25.8
  • 10
  •  
  • GAC035S
  • Threaded male
  • 1 1/2.
  •  
  • 20.1
  • 6
  • 3.36
  • A
  • Process Application
  • EC Fans
  • -
  • -
  • 6.64
  • 3.33
  •  
  • 1
  • 2
  • 4.6
  •  
  • 6.36
  • 36
  •  
  • 76.4
  •  
  • 17.6
  • 118
  • 31.2
  • 10
  •  
  • GAC040S
  • Threaded male
  • 1 1/2.
  •  
  • 24.6
  • 7.8
  • 3.14
  • A
  • Comfort Application
  • Standard Fans
  • 183
  • 4.66
  • -
  • -
  •  
  • 1
  • 2
  • 4.8
  •  
  • 6.92
  • 30
  •  
  • 76.4
  •  
  • 18.2
  • 117.6
  • 30.5
  • 10
  •  
  • GAC045S
  • Threaded male
  • 1 1/2.
  •  
  • 24.6
  • 7.8
  • 3.14
  • A
  • Comfort Application
  • EC Fans
  • 198
  • 5.02
  • -
  • -
  •  
  • 1
  • 2
  • 4.8
  •  
  • 7.85
  • 39
  •  
  • 75.7
  •  
  • 21
  • 147.9
  • 37.1
  • 10
  •  
  • GAC055S
  • Victaulic or Welded
  • 2.
  •  
  • 24.6
  • 7.8
  • 3.14
  • A
  • Process Application
  • EC Fans
  • -
  • -
  • 6.92
  • 3.53
  •  
  • 1
  • 2
  • 7
  •  
  • 9.45
  • 33
  •  
  • 77.8
  •  
  • 25.1
  • 140.6
  • 42.2
  • 10
  •  
  • GAC060S
  • Victaulic or Welded
  • 2.
  •  
  • 24.6
  • 7.8
  • 3.14
  • A
  • Process Application
  • Standard Fans
  • -
  • -
  • 6.79
  • 4.55
  •  
  • 1
  • 2
  • 8
  •  
  • 10.56
  • 40
  •  
  • 75.4
  •  
  • 28
  • 162.6
  • 47
  • 10
  •  
  • GAC070S
  • Victaulic or Welded
  • 2.
  •  
  • 54.8
  • 17.3
  • 3.17
  • A
  • Comfort Application
  • EC Fans
  • 193
  • 4.89
  • -
  • -
  •  
  • 1
  • 2
  • 8.5
  •  
  • 11.99
  • 18
  •  
  • 79.5
  •  
  • 30.9
  • 167.4
  • 51.8
  • 10
  •  
  • GAC080S
  • Victaulic or Welded
  • 2.
  •  
  • 54.8
  • 17.3
  • 3.17
  • A
  • Comfort Application
  • Standard Fans
  • 184
  • 4.67
  • -
  • -
  •  
  • 1
  • 2
  • 9.5
  •  
  • 14.26
  • 24
  •  
  • 81
  •  
  • 35.8
  • 210.5
  • 68.1
  • 10
  •  
  • GAC090S
  • Victaulic or Welded
  • 2 1/2.
  •  
  • 54.8
  • 17.3
  • 3.17
  • A
  • Process Application
  • Standard Fans
  • -
  • -
  • 6.3
  • 4.75
  •  
  • 1
  • 3
  • 12.5
  •  
  • 15.75
  • 29
  •  
  • 81
  •  
  • 41.1
  • 166.2
  • 69.8
  • 10
  •  
  • GAC110D
  • Victaulic or Welded
  • 2 1/2.
  •  
  • 54.8
  • 17.3
  • 3.17
  • A
  • Process Application
  • EC Fans
  • -
  • -
  • 6.43
  • 3.73
  •  
  • 2
  • 2-Feb
  • 13
  •  
  • 18.21
  • 42
  •  
  • 81
  •  
  • 49.5
  • 182.2
  • 83.8
  • 10
  •  
  • GAC110S
  • Victaulic or Welded
  • 2 1/2.
  •  
  • 61.2
  • 19.5
  • 3.14
  • A
  • Comfort Application
  • EC Fans
  • 183
  • 4.64
  • -
  • -
  •  
  • 1
  • 3
  • 12.5
  •  
  • 18.4
  • 25
  •  
  • 83.6
  •  
  • 48.4
  • 197.5
  • 82
  • 10
  •  
  • GAC125D
  • Victaulic or Welded
  • 2 1/2.
  •  
  • 61.2
  • 19.5
  • 3.14
  • A
  • Comfort Application
  • Standard Fans
  • 175
  • 4.44
  • -
  • -
  •  
  • 2
  • 2-Feb
  • 13.6
  •  
  • 21.25
  • 56
  •  
  • 83.6
  •  
  • 57.4
  • 212.3
  • 96.8
  • 10
  •  
  • GAC125S
  • Victaulic or Welded
  • 2 1/2.
  •  
  • 61.2
  • 19.5
  • 3.14
  • A
  • Process Application
  • EC Fans
  • -
  • -
  • 5.7
  • 3.63
  •  
  • 1
  • 3
  • 12.5
  •  
  • 21.1
  • 32
  •  
  • 84.2
  •  
  • 54.9
  • 245.8
  • 103.4
  • 10
  •  
  • GAC140D
  • Victaulic or Welded
  • 3.
  •  
  • 61.2
  • 19.5
  • 3.14
  • A
  • Process Application
  • Standard Fans
  • -
  • -
  • 5.69
  • 4.35
  •  
  • 2
  • 2-Feb
  • 16
  •  
  • 23.94
  • 46
  •  
  • 84.2
  •  
  • 63.2
  • 222
  • 106.5
  • 10
  •  
  • GAC160D
  • Victaulic or Welded
  • 3.
  •  
  • 69.5
  • 22.3
  • 3.12
  • A
  • Comfort Application
  • Standard Fans
  • 180
  • 4.57
  • -
  • -
  •  
  • 2
  • 2-Feb
  • 16.6
  •  
  • 27.94
  • 61
  •  
  • 84
  •  
  • 71.5
  • 278.5
  • 136.1
  • 10
  •  
  • GAC185D
  • Victaulic or Welded
  • 3.
  •  
  • 69.5
  • 22.3
  • 3.12
  • A
  • Comfort Application
  • EC Fans
  • 185
  • 4.71
  • -
  • -
  •  
  • 2
  • 2-Mar
  • 19.5
  •  
  • 31.91
  • 58
  •  
  • 85.1
  •  
  • 84.1
  • 292.2
  • 149.9
  • 10

  1. EUROVENT certified data, in accordance with standard EN 14511
    1. Cooling mode :
      • Evaporator water temperature = 12/7°C
      • Outdoor air temperature = 35°C
    2. Heating mode :
      • Condenser water temperature = 40/45°C
      • Outdoor air temperature = 7°C
  2. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN 14825.
  3. Seasonal energy efficiency - Cooling Mode : Following ecodesign regulation EU 2016/2281 on space cooling, normalized leaving water temperature at 7°C, in accordance with standard EN 14825.
  4. Seasonal Energy Performance Ratio - SEPR - High temperature (7°C) : Following ecodesign regulation EU 2016/2281 on process cooling units, normalized leaving water temperature at 7°C, in accordance with standard EN 14825.
  5. Seasonal Energy Performance Ratio - SEPR - Medium temperature (-8°C) Following ecodesign regulation EU 2015/1095 on process cooling chillers, normalized leaving water temperature at -8°C, in accordance with standard EN 14825
  6. Seasonal Coeficient of Performance - SCOP : SCOP in accordance with standard EN 14825. Heating mode performance is defined for average climate conditions.
  7. Seasonal energy efficiency - Heating Mode : Following ecodesign regulation EU 813/2013 on space heaters, normalized leaving water temperature at 7°C, in accordance with standard EN 14825, average climate conditions.
  8. Seasonal efficiency class - Following energy labelling regulation EU 811/2013 on space heaters.

Model Specification

  • Refrigeration Circuit
  • Product Index
  • Number Of Circuits
  • Number Of Compressors
  • Total Refrigirant Load R4101a
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Hydraulic Data
  • Type
  • Diameter
  • Evaporator Data
  • Nominal Water Flow Rate
  • Nominal pressure drop - kPa
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Absorbed Power - kW
  • Eer
  • Eurovent Energy Class
  • Application Type
  • Fan Type
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Seasonal Energy Performance Ratio High Temp
  • Seasonal Energy Performance Ratio Med Temp
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Seasonal Efficiency Class
  • Seasonal Coeficient Of Performance
  •  
  • GAH020S
  • 1
  • 2
  • 7
  •  
  • 9.9
  • 52.1
  • 16.6
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 3.45
  • 17
  •  
  • 72.4
  •  
  • 20
  • 6
  • 3.31
  • A
  • Comfort Application
  • EC Fans
  • 190
  • 4.67
  • -
  • -
  •  
  • 19.8
  • A+
  • 3.45
  •  
  • GAH025S
  • 1
  • 2
  • 7.4
  •  
  • 12.2
  • 61.7
  • 18.8
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 4.21
  • 25
  •  
  • 74
  •  
  • 20
  • 6
  • 3.31
  • A
  • Comfort Application
  • Standard Fans
  • 184
  • 4.67
  • -
  • -
  •  
  • 19.8
  • A+
  • 3.45
  •  
  • GAH030S
  • 1
  • 2
  • 8.3
  •  
  • 15.3
  • 88.7
  • 25.8
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 5.35
  • 26
  •  
  • 74
  •  
  • 20
  • 6
  • 3.31
  • A
  • Process Application
  • Standard Fans
  • -
  • -
  • 7.29
  • 4.77
  •  
  • 24.5
  • A+
  • 3.27
  •  
  • GAH035S
  • 1
  • 2
  • 8.8
  •  
  • 17.6
  • 118
  • 31.2
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 6.28
  • 35
  •  
  • 76.4
  •  
  • 20
  • 6
  • 3.31
  • A
  • Process Application
  • EC Fans
  • -
  • -
  • 7.29
  • 3.39
  •  
  • 24.5
  • A+
  • 3.46
  •  
  • GAH040S
  • 1
  • 2
  • 9
  •  
  • 18.2
  • 117.6
  • 30.5
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 6.8
  • 29
  •  
  • 76.4
  •  
  • 24.4
  • 8
  • 3.05
  • B
  • Comfort Application
  • EC Fans
  • 197
  • 4.84
  • -
  • -
  •  
  • 31.9
  • A+
  • 3.27
  •  
  • GAH045S
  • 1
  • 2
  • 9.2
  •  
  • 21
  • 147.9
  • 37.1
  • 10
  •  
  • Threaded male
  • 1 1/2
  •  
  • 7.71
  • 38
  •  
  • 75.7
  •  
  • 24.4
  • 8
  • 3.05
  • B
  • Comfort Application
  • Standard Fans
  • 177
  • 4.5
  • -
  • -
  •  
  • 31.9
  • A+
  • 3.37
  •  
  • GAH055S
  • 1
  • 2
  • 13.5
  •  
  • 25.1
  • 140.6
  • 42.2
  • 10
  •  
  • Victaulic or Welded
  • 2
  •  
  • 9.31
  • 32
  •  
  • 77.8
  •  
  • 24.4
  • 8
  • 3.05
  • B
  • Process Application
  • Standard Fans
  • -
  • -
  • 6.77
  • 4.56
  •  
  • 36.7
  • A+
  • 3.35
  •  
  • GAH060S
  • 1
  • 2
  • 17
  •  
  • 28
  • 162.6
  • 47
  • 10
  •  
  • Victaulic or Welded
  • 2
  •  
  • 10.37
  • 39
  •  
  • 75.4
  •  
  • 24.4
  • 8
  • 3.05
  • B
  • Process Application
  • EC Fans
  • -
  • -
  • 6.76
  • 3.52
  •  
  • 36.7
  • A+
  • 3.48
  •  
  • GAH070S
  • 1
  • 2
  • 18.4
  •  
  • 30.9
  • 167.4
  • 51.8
  • 10
  •  
  • Victaulic or Welded
  • 2
  •  
  • 11.8
  • 17
  •  
  • 79.5
  •  
  • 31
  • 11.2
  • 2.77
  • C
  • Comfort Application
  • EC Fans
  • 180
  • 4.42
  • -
  • -
  •  
  • 39.2
  • A+
  • 3.45
  •  
  • GAH080S
  • 1
  • 2
  • 18.4
  •  
  • 35.8
  • 210.5
  • 68.1
  • 10
  •  
  • Victaulic or Welded
  • 2
  •  
  • 14.04
  • 24
  •  
  • 81
  •  
  • 31
  • 11.2
  • 2.77
  • C
  • Comfort Application
  • Standard Fans
  • 163
  • 4.15
  • -
  • -
  •  
  • 39.2
  • A+
  • 3.33
  •  
  • GAH090S
  • 1
  • 3
  • 25
  •  
  • 41.1
  • 166.2
  • 69.8
  • 10
  •  
  • Victaulic or Welded
  • 2 1/2
  •  
  • 15.61
  • 29
  •  
  • 81
  •  
  • 31
  • 11.2
  • 2.77
  • C
  • Process Application
  • EC Fans
  • -
  • -
  • 5.85
  • 3.51
  •  
  • 44.6
  • A+
  • 3.32
  •  
  • GAH110D
  • 2
  • 2/2
  • 27.6
  •  
  • 49.5
  • 182.2
  • 83.8
  • 10
  •  
  • Victaulic or Welded
  • 2 1/2
  •  
  • 18.06
  • 41
  •  
  • 81
  •  
  • 31
  • 11.2
  • 2.77
  • C
  • Process Application
  • Standard Fans
  • -
  • -
  • 5.88
  • 4.26
  •  
  • 44.6
  • A+
  • 3.43
  •  
  • GAH110S
  • 1
  • 3
  • 27
  •  
  • 48.4
  • 197.5
  • 82
  • 10
  •  
  • Victaulic or Welded
  • 2 1/2
  •  
  • 18.21
  • 25
  •  
  • 83.6
  •  
  • 36.4
  • 12.4
  • 2.94
  • B
  • Comfort Application
  • EC Fans
  • 188
  • 4.64
  • -
  • -
  •  
  • 53.6
  • A+
  • 3.39
  •  
  • GAH125D
  • 2
  • 2/2
  • 29
  •  
  • 57.4
  • 212.3
  • 96.8
  • 10
  •  
  • Victaulic or Welded
  • 2 1/2
  •  
  • 20.87
  • 54
  •  
  • 83.6
  •  
  • 36.4
  • 12.4
  • 2.94
  • B
  • Comfort Application
  • Standard Fans
  • 168
  • 4.28
  • -
  • -
  •  
  • 53.6
  • A+
  • 3.57
  •  
  • GAH125S
  • 1
  • 3
  • 27.3
  •  
  • 54.9
  • 245.8
  • 103.4
  • 10
  •  
  • Victaulic or Welded
  • 2 1/2
  •  
  • 20.77
  • 31
  •  
  • 84.2
  •  
  • 36.4
  • 12.4
  • 2.94
  • B
  • Process Application
  • Standard Fans
  • -
  • -
  • 6.2
  • 4.64
  •  
  • 61.3
  • A+
  • 3.45
  •  
  • GAH140D
  • 2
  • 2/2
  • 35
  •  
  • 63.2
  • 222
  • 106.5
  • 10
  •  
  • Victaulic or Welded
  • 3
  •  
  • 23.54
  • 44
  •  
  • 84.2
  •  
  • 36.4
  • 12.4
  • 2.94
  • B
  • Process Application
  • EC Fans
  • -
  • -
  • 6.25
  • 3.62
  •  
  • 61.3
  • A+
  • 3.38
  •  
  • GAH160D
  • 2
  • 2/2
  • 37
  •  
  • 71.5
  • 278.5
  • 136.1
  • 10
  •  
  • Victaulic or Welded
  • 3
  •  
  • 27.48
  • 59
  •  
  • 84
  •  
  • 39.4
  • 13.5
  • 2.92
  • B
  • Comfort Application
  • Standard Fans
  • 170
  • 4.34
  • -
  • -
  •  
  • 67.6
  • A+
  • 3.49
  •  
  • GAH185D
  • 2
  • 3/2
  • 38
  •  
  • 84.1
  • 292.2
  • 149.9
  • 10
  •  
  • Victaulic or Welded
  • 3
  •  
  • 31.29
  • 56
  •  
  • 85.1
  •  
  • 39.4
  • 13.5
  • 2.92
  • B
  • Comfort Application
  • EC Fans
  • 190
  • 4.69
  • -
  • -
  •  
  • 67.6
  • A+
  • 3.57

  1. EUROVENT certified data, in accordance with standard EN 14511
    1. Cooling mode :
      • Evaporator water temperature = 12/7°C
      • Outdoor air temperature = 35°C
    2. Heating mode :
      • Condenser water temperature = 40/45°C
      • Outdoor air temperature = 7°C
  2. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN 14825.
  3. Seasonal energy efficiency - Cooling Mode : Following ecodesign regulation EU 2016/2281 on space cooling, normalized leaving water temperature at 7°C, in accordance with standard EN 14825.
  4. Seasonal Energy Performance Ratio - SEPR - High temperature (7°C) : Following ecodesign regulation EU 2016/2281 on process cooling units, normalized leaving water temperature at 7°C, in accordance with standard EN 14825.
  5. Seasonal Energy Performance Ratio - SEPR - Medium temperature (-8°C) Following ecodesign regulation EU 2015/1095 on process cooling chillers, normalized leaving water temperature at -8°C, in accordance with standard EN 14825
  6. Seasonal Coeficient of Performance - SCOP : SCOP in accordance with standard EN 14825. Heating mode performance is defined for average climate conditions.
  7. Seasonal energy efficiency - Heating Mode : Following ecodesign regulation EU 813/2013 on space heaters, normalized leaving water temperature at 7°C, in accordance with standard EN 14825, average climate conditions.
  8. Seasonal efficiency class - Following energy labelling regulation EU 811/2013 on space heaters.

Comfort and efficiency

Smart servicing

Being cool has never been so easy! The eComfort metrics are accessible 24/7 through LennoxCloud and LennoxHydrocontrol. These remote accesses to the machine enable permanent monitoring, local supervision and help predict maintenance operations, offering improved responsiveness.

Accoustic comfort

Three different noise level configurations are available. On top, a high-performance motor improves efficiency while reducing noise levels.

Heat recovery

Additional options enable rejected heat recovery to provide free hot water for sanitary or industrial purposes.

Excellent seasonal energy efficiencies

Its design, as well as its highly efficient components, ensure excellent seasonal energy efficiencies (SEER & SCOP). On top, the eDrive technology allows variable speed drive pumps, generating up to 75% reduction of the pump consumption.

A question?

Contact us for more information

Contact Lennox
Encountering difficulty?

Contact us for technical support on eComfort R410a

Contact Lennox

Product Resources and Files

HVAC Services

Get the most out of the equipment with our service offering, from the people who know it best

Maintenance

Regulatory support

System's modernisation

System's optimisation

Repairs

Spare parts

Looking for service related support?

Talk to our service team and get all the help you need to troubleshoot and service your equipment.

Contact Lennox