Looking for Refrigeration? Switch to

searchclose

Looking for Refrigeration? Switch to

chevron_left Products

chevron_left Air Conditioning & Heating

chevron_left Close Control Units

chevron_left Control & Supervision

home
flatair-front

Horizontal packaged air conditioner

Flatair

flatair-front

This indoor solution suits every building’s requirements while preserving its architecture! Designed for small places where comfort and efficiency are key priorities, it continuously ensures comfort.

R410A
Cooling capacity

22 - 33 kW

Heating capacity

20 - 29 kW

Airflow capacity

3700 - 5600 m3/h

Model Nomenclature

FA A M B H C 020 D S E M F 2 G M H

A FA = FLATAIR

B M = Packaged unit - S = Condensing unit (Outdoor unit / Split version) - I = Air treatment unit (Indoor unit / Split version)

C H = Heat pump unit

D Maximum cooling capacity in kW

E S = 1 circuit - D = 2 circuits

F M = R410A

G 2 = Revision number

H M = 400V/3/50Hz - T = 230V/1/50Hz

Model Specification

  • Ventilation Data
  • Product Index
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load
  • Nominal Thermal Performance Cooling
  • Cooling Capacity 1
  • Total Power Input - kW
  • Eer Net 1
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Seasonal Energy Efficiency Heating Mode
  • Eurovent Energy Efficiency Class Part Load Operation
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Seasonal Efficiencies Cooling Mode
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency Cooling Mode
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet 20c Water
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Cop Net
  •  
  • FAMH020
  • 1800
  • 3700
  • 4500
  •  
  • 12.4
  • 23.3
  • 23.3
  • 10
  •  
  • 1
  • 1
  • 6.6
  •  
  • 17.7
  • 6.3
  • 2.81
  •  
  • 3.32
  • 129.8
  • A
  •  
  • 83
  • 73
  •  
  • 4.25
  • 167.1
  •  
  • -
  • 4.5 / 15
  • -
  • -
  •  
  • 16.1
  • 3.6
  •  
  • FAMH035
  • 2800
  • 5600
  • 6200
  •  
  • 19.7
  • 35
  • 35
  • 10
  •  
  • 1
  • 1
  • 8
  •  
  • 27.2
  • 9.4
  • 2.91
  •  
  • 3.32
  • 129.7
  • B
  •  
  • 89
  • 78
  •  
  • 4.39
  • 172.5
  •  
  • -
  • 4.5 / 15
  • -
  • -
  •  
  • 22.6
  • 3.2

  1. Cooling Capacity - Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating Capacity - Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

Model Specification

  • Seasonal Efficiencies Heating Mode
  • Product Index
  • Seasonal Coefficient Of Performance - SCOP
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load - kg
  • Seasonal Efficiencies Cooling Mode
  • Seasonal Energy Efficiency Ratio - SEER
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  •  
  • FASH + FAIH020
  • 3.32
  • 129.8
  • A
  •  
  • 1.4 / 11.1
  • 2.3 / 21.2
  • 2.3 / 21.2
  • 10
  •  
  • 1800
  • 3700
  • 4500
  •  
  • 16.1
  • 4.5
  • 3.6
  •  
  • 83
  • 73
  •  
  • 1
  • 1
  • 6.6
  •  
  • 4.25
  •  
  • -
  • 4.5 / 15
  • -
  • -
  •  
  • 17.7
  • 6.3
  •  
  • FASH + FAIH035
  • 3.32
  • 129.7
  • B
  •  
  • 2.7 / 17
  • 4.3 / 30.9
  • 4.3 / 30.9
  • 10
  •  
  • 2800
  • 5600
  • 6200
  •  
  • 22.6
  • 7.1
  • 3.2
  •  
  • 89
  • 78
  •  
  • 1
  • 1
  • 8
  •  
  • 4.39
  •  
  • -
  • 4.5 / 15
  • -
  • -
  •  
  • 27.2
  • 9.4

  1. Cooling Capacity - Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating Capacity - Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

FGAS compliant

FGAS compliant

EcoDesign compliant

EcoDesign compliant

The perfect environment for food preparation and dining

Improving indoor air quality

Variable speed technology stabilizes the airflow and provides accurate supply temperature for improved indoor air quality.

Optimized efficiency

Efficiency optimization at full and part load operation thanks to variable speed compressor and EC fans on both sides.

High Adaptability

As a horizontal designed unit and with an A1 (M0) fireproof insulation, the Flatair is ideal for an installation in false ceiling, preserving the building’s architecture. Available as a package or as a split version it also comes with different airflow configurations to ensure perfect adaptability to every building structure.

Autonomous thermodynamic unit

This autonomous thermodynamic unit is able to provide cold and hot air, for indoor installation

Applications & Markets

Flatair for your applications

Food Retail Stores

Cafes & Restaurants

A question?

Contact us for more information

Contact Lennox
Encountering difficulty?

Contact us for technical support on Flatair

Contact Lennox

Complementary products

Products that help your Flatair work smoother and better

LennoxCloud

Multi-site & Multi-units connectivity solution

Product Resources and Files

Lennox EMEA Corporate Brochure

DM DISPLAY user manual for Flatair

flatair Installation, operation, maintenance manual

Lennox service catalogue

HVAC Services

Get the most out of the equipment with our service offering, from the people who know it best

Maintenance

Regulatory support

System's modernisation

System's optimisation

Repairs

Spare parts

Looking for service related support?

Talk to our service team and get all the help you need to troubleshoot and service your equipment.

Contact Lennox