Looking for Refrigeration? Switch to

searchclose

Looking for Refrigeration? Switch to

chevron_left Products

chevron_left Air Conditioning & Heating

chevron_left Close Control Units

chevron_left Control & Supervision

home
e-Baltic

Air-cooled rooftops units

e-Baltic

e-Baltic

Suitable for all retails, the e-Baltic is designed for large, open spaces, shopping malls, food retail, restaurants, logistic storages, etc. Economic, ecologic and highly adaptable, this sustainable and responsible unit will provide years of energy-efficient performance in all your buildings.

R32
Cooling capacity

30 - 207 kW

Heating capacity

31 - 207 kW

Airflow capacity

7000 - 35000 m3/h

+emeaProductNomenclature +emeaProductNomenclature.productRange_dotraw:e-baltic

Model Nomenclature

eB A B B H C 100 D D E P F 1 G M H

A eB = e-Baltic

B B = Steel - F = Aluminium

C H = Heat pump unit

D Cooling capacity in kW

E S = 1 circuit - D = 2 circuits

F P = R32 - H = HFO - N = No refrigerant

G Revision number

H 400V/3/50Hz

Model Specification

  • Ventilation Data
  • Product Index
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load R32
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Seasonal Efficiencies Cooling Mode
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  •  
  • eBBH035
  • 4200
  • 7000
  • 8000
  •  
  • 33.9
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water conditions.
  •  
  • 31.3
  • 9.5
  • 3.3
  •  
  • 1
  • 2
  • 5.1
  •  
  • 82
  • 80.2
  •  
  • 29.7
  • 7.94
  •  
  • 4.41
  • 173
  • B
  •  
  • 3.48
  •  
  • 14.5
  • 24.5
  • 82.2
  • 10
  •  
  • eBBH045
  • 4500
  • 7500
  • 10000
  •  
  • 33.9
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water conditions.
  •  
  • 43
  • 13.86
  • 3.1
  •  
  • 1
  • 2
  • 6.75
  •  
  • 83
  • 81.5
  •  
  • 37.2
  • 10.54
  •  
  • 4.41
  • 173
  • B
  •  
  • 3.29
  •  
  • 21.3
  • 34.2
  • 112.1
  • 10
  •  
  • eBBH055
  • 5000
  • 8000
  • 11200
  •  
  • 57.2
  • 27 / 54
  • 24 / 48
  • Capacity depends on air and water conditions.
  •  
  • 45.9
  • 14.89
  • 3.08
  •  
  • 2
  • 4
  • 6.2 / 6.2
  •  
  • 74.1
  • 75.5
  •  
  • 43
  • 12.61
  •  
  • 3.99
  • 157
  • B
  •  
  • 3.45
  •  
  • 22.6
  • 98.4
  • 39.3
  • 10
  •  
  • eBBH065
  • 6600
  • 11000
  • 16000
  •  
  • 57.2
  • 27 / 54
  • 24 / 48
  • Capacity depends on air and water conditions.
  •  
  • 57.6
  • 19.86
  • 2.9
  •  
  • 2
  • 4
  • 6.2 / 6.2
  •  
  • 76.4
  • 80.8
  •  
  • 56.5
  • 16.57
  •  
  • 3.93
  • 154
  • B
  •  
  • 3.26
  •  
  • 26.6
  • 102.6
  • 44.9
  • 10
  •  
  • eBBH075
  • 9500
  • 13500
  • 22000
  •  
  • 74.1
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 66.7
  • 22.48
  • 2.97
  •  
  • 2
  • 4
  • 5.7 / 5.7
  •  
  • 79
  • 82.2
  •  
  • 64.3
  • 18.71
  •  
  • 3.98
  • 156
  • B
  •  
  • 3.52
  •  
  • 33.3
  • 118.3
  • 56
  • 10
  •  
  • eBBH085
  • 9600
  • 16000
  • 22000
  •  
  • 74.1
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 81
  • 28.44
  • 2.85
  •  
  • 2
  • 4
  • 5.7 / 5.7
  •  
  • 81.7
  • 86.2
  •  
  • 83
  • 25.8
  •  
  • 3.71
  • 145
  • B
  •  
  • 3.26
  •  
  • 37.9
  • 130.4
  • 63.4
  • 10
  •  
  • eBBH095
  • 12300
  • 20500
  • 23000
  •  
  • 101.5
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 98.4
  • 30.37
  • 3.24
  •  
  • 2
  • 4
  • 7.7 / 7.7
  •  
  • 81.4
  • 85.2
  •  
  • 92.7
  • 24.14
  •  
  • 4.51
  • 177
  • B
  •  
  • 3.38
  •  
  • 47.8
  • 162.7
  • 75.8
  • 10
  •  
  • eBBH100
  • 15000
  • 20500
  • 23000
  •  
  • 95.4
  • 30 / 72
  • -
  • Capacity depends on air and water conditions.
  •  
  • 97.5
  • 31.05
  • 3.14
  •  
  • 2
  • 4
  • 7.3 / 7.3
  •  
  • 81.4
  • 85.2
  •  
  • 93.5
  • 24.6
  •  
  • 4.5
  • 177
  • B
  •  
  • 3.4
  •  
  • 47.9
  • 162.9
  • 76
  • 10
  •  
  • eBBH115
  • 13800
  • 23000
  • 23000
  •  
  • 101.5
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 117.1
  • 38.52
  • 3.04
  •  
  • 2
  • 4
  • 7.8 / 7.8
  •  
  • 83.2
  • 87.7
  •  
  • 114
  • 31.84
  •  
  • 4.26
  • 167
  • B
  •  
  • 3.37
  •  
  • 55.8
  • 212.6
  • 93.6
  • 10
  •  
  • eBBH120
  • 15700
  • 23000
  • 23000
  •  
  • 95.4
  • 30 / 72
  • -
  • Capacity depends on air and water conditions.
  •  
  • 117.7
  • 38.59
  • 3.05
  •  
  • 2
  • 4
  • 7.4 / 7.4
  •  
  • 83.7
  • 87.7
  •  
  • 115
  • 32.86
  •  
  • 4.2
  • 165
  • B
  •  
  • 3.34
  •  
  • 56.3
  • 213.5
  • 94.5
  • 10
  •  
  • eBBH130
  • 19000
  • 26000
  • 35000
  •  
  • 139.2
  • 45 / 108
  • -
  • Capacity depends on air and water conditions.
  •  
  • 134.7
  • 45.36
  • 2.97
  •  
  • 2
  • 4
  • 11.25 / 10.5
  •  
  • 84.5
  • 89.4
  •  
  • 129.3
  • 34.95
  •  
  • 4.29
  • 169
  • B
  •  
  • 3.39
  •  
  • 62.6
  • 202.8
  • 98.4
  • 10
  •  
  • eBBH150
  • 21000
  • 28000
  • 35000
  •  
  • 139.2
  • 45 / 108
  • -
  • Capacity depends on air and water conditions.
  •  
  • 150.2
  • 51.09
  • 2.94
  •  
  • 2
  • 4
  • 11.25 / 10.5
  •  
  • 86.4
  • 91
  •  
  • 145.9
  • 41.1
  •  
  • 4.23
  • 166
  • B
  •  
  • 3.39
  •  
  • 68.8
  • 230.2
  • 108.6
  • 10
  •  
  • eBBH180
  • 24000
  • 33000
  • 43000
  •  
  • 172.9
  • 72 / 162
  • -
  • Capacity depends on air and water conditions.
  •  
  • 180
  • 57.51
  • 3.13
  •  
  • 2
  • 4
  • 12.8 / 12.8
  •  
  • 85.7
  • 88.6
  •  
  • 172.9
  • 45.86
  •  
  • 4.31
  • 169
  • B
  •  
  • 3.4
  •  
  • 82
  • 273.8
  • 129.4
  • 10
  •  
  • eBBH210
  • 28000
  • 35000
  • 43000
  •  
  • 172.9
  • 72 / 162
  • -
  • Capacity depends on air and water conditions.
  •  
  • 206.7
  • 71.27
  • 2.9
  •  
  • 2
  • 4
  • 13.5 / 13.5
  •  
  • 87.5
  • 89.8
  •  
  • 207
  • 59.65
  •  
  • 3.81
  • 149
  • B
  •  
  • 3.35
  •  
  • 98.6
  • 328.7
  • 155.4
  • 10

  1. Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. SEER: SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling mode: Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance: SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficient - Heating mode: Space heating energy efficiency following Ecodesign regulation EU 2016/2281

Model Specification

  • Ventilation Data
  • Product Index
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load R32
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Seasonal Efficiencies Cooling Mode
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  •  
  • eBBH035
  • 4200
  • 7000
  • 8000
  •  
  • 33.9
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water conditions.
  •  
  • 31.3
  • 9.5
  • 3.3
  •  
  • 1
  • 2
  • 5.1
  •  
  • 82
  • 80.2
  •  
  • 29.7
  • 7.94
  •  
  • 4.41
  • 173
  • B
  •  
  • 3.48
  •  
  • 14.5
  • 24.5
  • 82.2
  • 10
  •  
  • eBBH045
  • 4500
  • 7500
  • 10000
  •  
  • 33.9
  • 18 / 36
  • 18 / 36
  • Capacity depends on air and water conditions.
  •  
  • 43
  • 13.86
  • 3.1
  •  
  • 1
  • 2
  • 6.75
  •  
  • 83
  • 81.5
  •  
  • 37.2
  • 10.54
  •  
  • 4.41
  • 173
  • B
  •  
  • 3.29
  •  
  • 21.3
  • 34.2
  • 112.1
  • 10
  •  
  • eBBH055
  • 5000
  • 8000
  • 11200
  •  
  • 57.2
  • 27 / 54
  • 24 / 48
  • Capacity depends on air and water conditions.
  •  
  • 45.9
  • 14.89
  • 3.08
  •  
  • 2
  • 4
  • 6.2 / 6.2
  •  
  • 74.1
  • 75.5
  •  
  • 43
  • 12.61
  •  
  • 3.99
  • 157
  • B
  •  
  • 3.45
  •  
  • 22.6
  • 98.4
  • 39.3
  • 10
  •  
  • eBBH065
  • 6600
  • 11000
  • 16000
  •  
  • 57.2
  • 27 / 54
  • 24 / 48
  • Capacity depends on air and water conditions.
  •  
  • 57.6
  • 19.86
  • 2.9
  •  
  • 2
  • 4
  • 6.2 / 6.2
  •  
  • 76.4
  • 80.8
  •  
  • 56.5
  • 16.57
  •  
  • 3.93
  • 154
  • B
  •  
  • 3.26
  •  
  • 26.6
  • 102.6
  • 44.9
  • 10
  •  
  • eBBH075
  • 9500
  • 13500
  • 22000
  •  
  • 74.1
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 66.7
  • 22.48
  • 2.97
  •  
  • 2
  • 4
  • 5.7 / 5.7
  •  
  • 79
  • 82.2
  •  
  • 64.3
  • 18.71
  •  
  • 3.98
  • 156
  • B
  •  
  • 3.52
  •  
  • 33.3
  • 118.3
  • 56
  • 10
  •  
  • eBBH085
  • 9600
  • 16000
  • 22000
  •  
  • 74.1
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 81
  • 28.44
  • 2.85
  •  
  • 2
  • 4
  • 5.7 / 5.7
  •  
  • 81.7
  • 86.2
  •  
  • 83
  • 25.8
  •  
  • 3.71
  • 145
  • B
  •  
  • 3.26
  •  
  • 37.9
  • 130.4
  • 63.4
  • 10
  •  
  • eBBH095
  • 12300
  • 20500
  • 23000
  •  
  • 101.5
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 98.4
  • 30.37
  • 3.24
  •  
  • 2
  • 4
  • 7.7 / 7.7
  •  
  • 81.4
  • 85.2
  •  
  • 92.7
  • 24.14
  •  
  • 4.51
  • 177
  • B
  •  
  • 3.38
  •  
  • 47.8
  • 162.7
  • 75.8
  • 10
  •  
  • eBBH100
  • 15000
  • 20500
  • 23000
  •  
  • 95.4
  • 30 / 72
  • -
  • Capacity depends on air and water conditions.
  •  
  • 97.5
  • 31.05
  • 3.14
  •  
  • 2
  • 4
  • 7.3 / 7.3
  •  
  • 81.4
  • 85.2
  •  
  • 93.5
  • 24.6
  •  
  • 4.5
  • 177
  • B
  •  
  • 3.4
  •  
  • 47.9
  • 162.9
  • 76
  • 10
  •  
  • eBBH115
  • 13800
  • 23000
  • 23000
  •  
  • 101.5
  • 27 / 54
  • 36 / 72
  • Capacity depends on air and water conditions.
  •  
  • 117.1
  • 38.52
  • 3.04
  •  
  • 2
  • 4
  • 7.8 / 7.8
  •  
  • 83.2
  • 87.7
  •  
  • 114
  • 31.84
  •  
  • 4.26
  • 167
  • B
  •  
  • 3.37
  •  
  • 55.8
  • 212.6
  • 93.6
  • 10
  •  
  • eBBH120
  • 15700
  • 23000
  • 23000
  •  
  • 95.4
  • 30 / 72
  • -
  • Capacity depends on air and water conditions.
  •  
  • 117.7
  • 38.59
  • 3.05
  •  
  • 2
  • 4
  • 7.4 / 7.4
  •  
  • 83.7
  • 87.7
  •  
  • 115
  • 32.86
  •  
  • 4.2
  • 165
  • B
  •  
  • 3.34
  •  
  • 56.3
  • 213.5
  • 94.5
  • 10
  •  
  • eBBH130
  • 19000
  • 26000
  • 35000
  •  
  • 139.2
  • 45 / 108
  • -
  • Capacity depends on air and water conditions.
  •  
  • 134.7
  • 45.36
  • 2.97
  •  
  • 2
  • 4
  • 11.25 / 10.5
  •  
  • 84.5
  • 89.4
  •  
  • 129.3
  • 34.95
  •  
  • 4.29
  • 169
  • B
  •  
  • 3.39
  •  
  • 62.6
  • 202.8
  • 98.4
  • 10
  •  
  • eBBH150
  • 21000
  • 28000
  • 35000
  •  
  • 139.2
  • 45 / 108
  • -
  • Capacity depends on air and water conditions.
  •  
  • 150.2
  • 51.09
  • 2.94
  •  
  • 2
  • 4
  • 11.25 / 10.5
  •  
  • 86.4
  • 91
  •  
  • 145.9
  • 41.1
  •  
  • 4.23
  • 166
  • B
  •  
  • 3.39
  •  
  • 68.8
  • 230.2
  • 108.6
  • 10
  •  
  • eBBH180
  • 24000
  • 33000
  • 43000
  •  
  • 172.9
  • 72 / 162
  • -
  • Capacity depends on air and water conditions.
  •  
  • 180
  • 57.51
  • 3.13
  •  
  • 2
  • 4
  • 12.8 / 12.8
  •  
  • 85.7
  • 88.6
  •  
  • 172.9
  • 45.86
  •  
  • 4.31
  • 169
  • B
  •  
  • 3.4
  •  
  • 82
  • 273.8
  • 129.4
  • 10
  •  
  • eBBH210
  • 28000
  • 35000
  • 43000
  •  
  • 172.9
  • 72 / 162
  • -
  • Capacity depends on air and water conditions.
  •  
  • 206.7
  • 71.27
  • 2.9
  •  
  • 2
  • 4
  • 13.5 / 13.5
  •  
  • 87.5
  • 89.8
  •  
  • 207
  • 59.65
  •  
  • 3.81
  • 149
  • B
  •  
  • 3.35
  •  
  • 98.6
  • 328.7
  • 155.4
  • 10

  1. Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. SEER: SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling mode: Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance: SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficient - Heating mode: Space heating energy efficiency following Ecodesign regulation EU 2016/2281

FGAS compliant

FGAS compliant

EcoDesign compliant

EcoDesign compliant

Eurovent Certified performance

Eurovent Certified performance

First R32 rooftop

Eco-friendly solution

The e-Baltic uses R32, a refrigerant that has a low GWP (Global Warming Potential) and helps you reduce your carbon footprint. Additionally, its eco-design optimizes energy consumption.

Economic

Thanks to R32 Refrigerant, easily available and affordable with low GWP, you can reduce environmental taxes by up to 75%.

Better comfort and energy saving

The e-Baltic meets the 2021 EcoDesign seasonal efficiency requirements and ensures optimized energy consumption. On top, its features enable the unit to adjust its power and airflow according to real climatic conditions; and thus generate significant energy savings. Low sound level thanks to several acoustic attenuation options available.

Adaptability

The unit’s compact nature makes it easy to install and ensures a perfect integration into its environment. Moreover, several airflow configurations ventilation options, and roofcurbs design are available in order to fit the best your building’s needs. Additionally, the replacement of an old unit is highly facilitated due to compact dimensions and the footprint of e-Baltic units, which does not affect the aesthetics of the buildings.

Fresh Air and Free Cooling

Fresh air management and Free Cooling are standard features of e-Baltic that can reduce annual energy consumption. Different Energy Recovery technologies are available to make fresh air management easier and more efficient than ever.

Applications & Markets

e-Baltic for your applications

Food Retail Stores

Non-food Retail Stores

Shopping Malls

Cafes & Restaurants

Cultural and sport centres

Storage & Logistics

A question?

Contact us for more information

Contact Lennox
Encountering difficulty?

Contact us for technical support on e-Baltic

Contact Lennox

Complementary products

Products that help your e-Baltic work smoother and better

LennoxCloud

Multi-site & Multi-units connectivity solution

e-savvy

Smart building management system

Product Resources and Files

Lennox EMEA Corporate Brochure

e-Baltic Installation, operation, maintenance manual

e-Baltic Installation, operation, maintenance manual-PPT

E-recovery coils in rooftops for e-Baltic

RECOVERY MODULE INSTALLATION PROCESS FOR E-BALTIC

Lennox service catalogue

HVAC Services

Get the most out of the equipment with our service offering, from the people who know it best

Maintenance

Regulatory support

System's modernisation

System's optimisation

Repairs

Spare parts

Looking for service related support?

Talk to our service team and get all the help you need to troubleshoot and service your equipment.

Contact Lennox